raid
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
raid [2009/11/16 14:26] – 172.26.0.166 | raid [2009/11/17 05:59] – 172.26.0.166 | ||
---|---|---|---|
Line 79: | Line 79: | ||
# mdadm /dev/md3 --fail /dev/hda1 --remove /dev/hda1 | # mdadm /dev/md3 --fail /dev/hda1 --remove /dev/hda1 | ||
# mdadm /dev/md4 --fail /dev/hda6 --remove / | # mdadm /dev/md4 --fail /dev/hda6 --remove / | ||
+ | <note warning> You must Shutdown the server before you physically remove the drive! </ | ||
Shut the server down and replace the faulty drive with a new one. After booting your drive letters may have shifted around, so just be sure to verify which is which before proceeding. | Shut the server down and replace the faulty drive with a new one. After booting your drive letters may have shifted around, so just be sure to verify which is which before proceeding. | ||
Clone the partition table from the good drive to the bad one: | Clone the partition table from the good drive to the bad one: | ||
Line 115: | Line 115: | ||
30716160 blocks [2/2] [UU] | 30716160 blocks [2/2] [UU] | ||
| | ||
- | unused devices: < | + | unused devices: < |
Clearing any previous raid info on a disk (eg. reusing a disk from another decommissioned raid array) | Clearing any previous raid info on a disk (eg. reusing a disk from another decommissioned raid array) | ||
Line 135: | Line 135: | ||
How do you know which physical disk is broken to replace it? | How do you know which physical disk is broken to replace it? | ||
+ | f | ||
===== Hardware RAID ===== | ===== Hardware RAID ===== |