raid [2009/09/29 15:02] 172.26.0.166raid [2009/11/16 13:59] 172.26.0.166
Line 5: Line 5:
 ==== Drive numbering ==== ==== Drive numbering ====
  
-If you're looking at the front of the HPC you'll see four rows of drives.  From the bottom;+If you're looking at the front of the HPC you'll see four rows of drives.  From the bottom:
   * Rows 0 - 2 are SATA, connected to the hardware 3ware RAID card   * Rows 0 - 2 are SATA, connected to the hardware 3ware RAID card
   * Row 3 are IDE   * Row 3 are IDE
Line 50: Line 50:
              
 unused devices: <none></code> unused devices: <none></code>
 +
 +==== Repair RAID ====
 +
 +Setting a disk faulty/failed:
 +
 +# mdadm --fail /dev/md0 /dev/hdc1
 +
 +DO NOT run this every on a raid0 or linear device or your data is toasted!
 +
 +Removing a faulty disk from an array:
 +
 +# mdadm --remove /dev/md0 /dev/hdc1
 +Clearing any previous raid info on a disk (eg. reusing a disk from another decommissioned raid array)
 +
 +# mdadm --zero-superblock /dev/hdc1
 +Adding a disk to an array
 +
 +# mdadm --add /dev/md0 /dev/hdc1
 +
  
 === To Do list: === === To Do list: ===
Line 65: Line 84:
 ===== Hardware RAID ===== ===== Hardware RAID =====
  
-There is a utility, tw_cli, which can be used to control the hardware raid.  The hardware RAID has three arrays, all RAID 5.  Each "unit" (row) is one array.+A 3ware 9500S SATA RAID card using the 3w-9xxx kernel module.  It has 12 channels.  The HPC is configured to use RAID5 for all of its RAID arrays on the hardware RAID.
  
-| 8 | 9 | 10 | 11 | +==== Physical Disk Layout ==== 
-| 4 | 5 | 6 | 7 | + 
-| 0 | 1 | 2 | 3 |+We have one RAID controller, 'c1' Disks are plugged into ports, 'p1' - 'p11' The disks are then grouped into units (basically the rows), 'u0' - 'u2'
 + 
 +Port 8 | Port 9 | Port 10 | Port 11 | 
 +Port 4 | Port 5 | Port 6 | Port 7 | 
 +Port 0 | Port 1 | Port 2 | Port 3 | 
 + 
 +==== Repairing 'degraded' arrays ==== 
 + 
 +There is a utility, tw_cli, which can be used to control/monitor the hardware raid controller.
  
 Study the output of ''show'' to know which controller to manage.  Then you can use ''/c1 show'' to show the status of that particular controller.  Things to look for: Study the output of ''show'' to know which controller to manage.  Then you can use ''/c1 show'' to show the status of that particular controller.  Things to look for:
   * Which controller is active? (c0, c1, etc)   * Which controller is active? (c0, c1, etc)
   * Which unit is degraded? (u0, u1, u2, etc)   * Which unit is degraded? (u0, u1, u2, etc)
-  * Which +  * Which port is inactive or missing? (p1, p5, etc) 
 + 
 +<note warning>The controller supports hot swapping but you **must** remove a faulty drive through the ''tw_cli'' tool before you can swap drives.</note>
  
 Remove the faulty port: Remove the faulty port:
Line 82: Line 111:
 Rebuild the degraded array: Rebuild the degraded array:
 <code>maint rebuild c1 u2 p5</code> <code>maint rebuild c1 u2 p5</code>
-Check the status of the rebuild by monitoring ''/c1 show''+ 
 +Check the status of the rebuild by monitoring ''/c1 show'', but I have a feeling this might disturb the rebuild process.  In any case, you can check the status by following the output of ''dmesg'': 
 + 
 +<file>3w-9xxx: scsi1: AEN: INFO (0x04:0x000B): Rebuild started:unit=2. 
 +3w-9xxx: scsi1: AEN: INFO (0x04:0x0005): Background rebuild done:unit=2.</file> 
 + 
 +This sucks: 
 + 
 +<file>3w-9xxx: scsi1: AEN: INFO (0x04:0x0029): Background verify started:unit=0. 
 +3w-9xxx: scsi1: AEN: INFO (0x04:0x002B): Background verify done:unit=0. 
 +3w-9xxx: scsi1: AEN: ERROR (0x04:0x0002): Degraded unit detected:unit=0, port=3</file> 
 + 
 +<code>$ sudo tw_cli  
 +Password:  
 +//hpc-ilri> /c1 show 
 + 
 +Unit  UnitType  Status         %RCmpl  %V/I/ Stripe  Size(GB)  Cache  AVrfy 
 +------------------------------------------------------------------------------ 
 +u0    RAID-5    DEGRADED                   64K     698.461   ON     OFF     
 +u1    RAID-5    OK                         64K     698.461   ON     OFF     
 +u2    RAID-5    OK                         64K     698.461   ON     OFF     
 + 
 +Port   Status           Unit   Size        Blocks        Serial 
 +--------------------------------------------------------------- 
 +p0     OK               u0     232.88 GB   488397168     WD-WMAEP2714804      
 +p1     OK               u0     232.88 GB   488397168     WD-WMAEP1570106      
 +p2     OK               u0     232.88 GB   488397168     WD-WMAEP2712887      
 +p3     DEGRADED         u0     232.88 GB   488397168     WD-WMAEP2714418      
 +p4     OK               u2     232.88 GB   488397168     WD-WCAT1C715001      
 +p5     OK               u2     232.88 GB   488397168     WD-WMAEP2713449      
 +p6     OK               u2     232.88 GB   488397168     WD-WMAEP2715070      
 +p7     OK               u2     232.88 GB   488397168     WD-WMAEP2712590      
 +p8     OK               u1     232.88 GB   488397168     WD-WMAEP2712574      
 +p9     OK               u1     232.88 GB   488397168     WD-WMAEP2734142      
 +p10    OK               u1     232.88 GB   488397168     WD-WMAEP2702155      
 +p11    OK               u1     232.88 GB   488397168     WD-WMAEP2712472  </code> 
 + 
 +Looks like another drive failed.