raid [2009/08/27 09:22] 172.26.0.166raid [2009/09/29 15:01] 172.26.0.166
Line 1: Line 1:
-=== HPC RAID array === +===== RAID ===== 
-The storage on the HPC is using a RAID array. (Level?)+We have two RAIDs on the HPC 
 +  * Linux kernel software RAID 
 +  * 3mware hardware RAID 
 +==== Drive numbering ====
  
-It is currently reporting a degraded array (27 Aug 2009):+If you're looking at the front of the HPC you'll see four rows of drives.  From the bottom; 
 +  * Rows 0 - 2 are SATA, connected to the hardware 3ware RAID card 
 +  * Row 3 are IDE
  
-<code>#cat /proc/mdstat +===== Software RAID ===== 
-Personalities : [raid0] [raid1]  +The Linux kernel has the ''md'' (mirrored devices) driver for software RAID devices.  There are currently two 80 GB IDE hard drives connected to the server, ''/dev/hda'' and ''/dev/hdd'' These were set up as five RAID devices during the install of Rocks/CentOS. 
-md1 : active raid1 hda1[0] + 
-      129920 blocks [2/1] [U_]+Here is information on their configuration: 
 + 
 +<code># mount | grep md 
 +/dev/md0 on / type ext3 (rw) 
 +/dev/md3 on /boot type ext3 (rw) 
 +/dev/md2 on /scratch type ext3 (rw) 
 +/dev/md1 on /export type ext3 (rw)</code> 
 + 
 +It should be noted that ''/dev/md4'' is being used as swap: 
 +<code># swapon -s 
 +Filename Type Size Used Priority 
 +/dev/md4                                partition 2168632 0 -1</code> 
 + 
 +A snapshot of the software RAID's health: 
 + 
 +<code># cat /proc/mdstat  
 +Personalities : [raid1] [raid0]  
 +md3 : active raid1 hdd1[1] hda1[0] 
 +      200704 blocks [2/2] [UU]
              
-md3 : active raid1 hdc3[1] hda3[0] +md1 : active raid1 hdd3[1] hda3[0] 
-      2097024 blocks [2/2] [UU]+      26627648 blocks [2/2] [UU]
              
-md2 : active raid1 hdc5[1] +md2 : active raid0 hdd5[1] hda5[0
-      65437696 blocks [2/1] [_U]+      36868608 blocks 256k chunks
              
-md0 : active raid0 hdc2[1] hda2[0] +md4 : active raid1 hdd6[1] hda6[0] 
-      20971008 blocks 256k chunks+      2168640 blocks [2/2] [UU] 
 +       
 +md0 : active raid1 hdd2[1] hda2[0] 
 +      30716160 blocks [2/2] [UU]
              
 unused devices: <none></code> unused devices: <none></code>
Line 31: Line 57:
 How do you know which physical disk is broken to replace it? How do you know which physical disk is broken to replace it?
  
 +
 +===== Hardware RAID =====
 +
 +There is a utility, tw_cli, which can be used to control the hardware raid.  The hardware RAID has three arrays, all RAID 5.  Each "unit" (row) is one array.
 +
 +| 8 | 9 | 10 | 11 |
 +| 4 | 5 | 6 | 7 |
 +| 0 | 1 | 2 | 3 |
 +
 +Study the output of ''show'' to know which controller to manage.  Then you can use ''/c1 show'' to show the status of that particular controller.  Things to look for:
 +  * Which controller is active? (c0, c1, etc)
 +  * Which unit is degraded? (u0, u1, u2, etc)
 +  * Which 
 +
 +Remove the faulty port:
 +<code>maint remove c1 p5</code>
 +Insert a new drive and rescan:
 +<code>maint rescan</code>
 +Rebuild the degraded array:
 +<code>maint rebuild c1 u2 p5</code>
 +Check the status of the rebuild by monitoring ''/c1 show''
raid.txt · Last modified: 2010/09/19 23:58 by aorth